Diffusing Wave Spectroscopy (DWS)
- The DWS RheoLab is an optical rheometer.
- It provides access to the sample's viscoelastic properties over an unmatched frequency range and enables the study of textures and microstructures while requiring only small sample volumes.
- Since the measurements are contact-free and non-destructive, the use of a tightly sealed sample cell allows studies of stability or shelf-life over long periods for highly viscoelastic and fragile microstructures.
- Ideally suited for a wide range of viscoelastic samples, including polymers, microgels, protein solutions, emulsions, particle suspensions, dairy, and cosmetic products.

Interfacial Tension/ Contact Angle Analyzer
- Enables solids and liquids in wetting and coating processes to be analyzed comprehensively.
- Provides contact angle and surface tension results.

Anton Paar MCR702 Rheometer
-
Special accessories for DMA and DMTA measurements, rheo-optics, magneto- and electrorheology, interfacial rheology, UV curing and many other applications
-
Temperature range: –150 °C to 1000 °C
- Torque range: 1 nNm to 230 nNm (rotation) and 0.5 nNm to 230 nNm (oscillation)
- Angular velocity range: 0 rad/s to 314 rad/s
- Angular frequency range: 10-7 rad/s to 628 rad/s
-
Angular deflection range: 0.05 µrad to ∞ (set value)
- Normal force range: -50 N to 50 N
- Magnetic field: 0 to 3 T

Leica DMi8 Inverted Fluorescent Microscope
- Options for transparent lighting: bright field, dark field and phase contrast
- Fluorescence filter sets: DAPI, FITC and RHOD
- Adjustment of viewing position (tile scanning or mark & find) and focus (extended depth of focus) during the image recording process
- Time-lapse image capture series

Small Angle Light Scattering
- Small-angle scattering (SAS) is a scattering technique based on deflection of collimated radiation away from the straight trajectory after it interacts with structures that are much larger than the wavelength of the radiation.
- The deflection is small (0.1-10°).
- It can give information about the size, shape and orientation of structures in a sample.
- It is a powerful technique for investigating large-scale structures from 10 Å up to thousands and even several tens of thousands of angstroms.

RIGOL DP811A DC Power Supply
- 2 Ranges; total power up to 200W
- Low Ripple Noise <350 uVrms/2mVpp
- Fast transient response time: <50 us
- Up to 10A or 40 V
- OVP/OCP/OTP protection functions
- Built in V, A, W measurements and waveform display
- Support for output Delay, Analysis, Monitor, and Preset functions
- 3.5 inch TFT Display
- Connectivity including USB Host & Device, LAN, and Digital IO

Keysight 33210A Function/Waveform Generator
-
10 MHz Sine and Square waveforms
- Pulse, Ramp, Triangle, Noise, and DC waveforms
- Optional 14-bit, 50 MSa/s, 8K point Arbitrary Waveform Generator
- AM, FM, and PWM modulation types
- Linear & logarithmic sweeps and burst operation
- 10 mVpp to 10 Vpp amplitude range
- Graph mode for visual verification of signal settings
- Connect via USB, GPIB and LAN
- Fully compliant to LXI Class C specification
- Power Rating: 100-240 V @ 50/60 Hz, 100-120 V @ 400 Hz

QSONICA Sonicator
- Power Rating: 500 Watts
- Frequency: 20 kHz
- Programmable Timer: 10 Hours
- Adjustable Pulse On/Off: 1 Second to 1 Minute
- Dimensions: 8" W x 15.25" L x 8.5" H
- Voltage: 110V, 50/60Hz

Hach pH HQ440D Benchtop Meter
- pH measurement range: 0 to 14 pH
- pH Resolution: 0.001/0.01/0.1 pH
- Operating temperature range: 0 °C to 60 °C

Chemat Technology Spin Coater KW-4A
- Power: 115 VAC, 60 Hz, 1 Amp 220 VAC, 50 Hz, 1 Amp
- Stage 1: 500 rpm to 2500 rpm, 2 to 18 Seconds (2-Stage Spinning)
- Stage 2: 1000 rpm to 8000 rpm, 3 to 60 Seconds
- Vacuum: 2.1 CFM
- Speed Stability: <1%
- Front Panel Controls: Digital Readout in Speed 1000 rpm
- Timer Controls: Stage I and Stage II
- Speed Controls: Stage I and Stage II
- Control switch
- Vacuum switch
- Power switch
- Start switch
- Dimension (D x W x H):10 x 8.5 x 8.5 in. (25.4 x 21.5 x 21.5 cm)
- Weight: 15 lbs (6.8 kg)

Fisherbrand™ Variable Speed Mini Vortex Mixer
- Speed: 500 rpm to 2800 rpm
- Dimension: 3.8 in. x 3.8 in. x 4.2 in.

CAT X 1000 UNIDrive Homogenizer
- Power supply: 115VAC 60Hz
- Motor power: 1050W
- Speed range: 4.000 rpm to 33.000 rpm

ECLIPSE Ti2-A Inverted Microscope
- Operating temperature: 0℃ to 40℃
- Operating humidity: 60% RH max. (at 40℃, no condensation)

High-voltage Power Amplifier
- Operation temperature: 0 °C to 40 °C
-
Relative humidity: to 85%, non-condensing
-
Output voltage range: 0 to ±10 kV DC or peak AC
-
Output current range: 0 to ±10 mA DC or ±40 mA peak for 1 ms
-
Gain: 1000 V/V
-
Slew rate: Greater than 700 V/μs (10% to 90%, typical)
- Large signal bandwidth: DC to greater than 19.5 kHz

Transmission Flow Cell (Model FC 285)
- Dimension: 2.0” × 0.5” × 0.10”
- Maximum flow rate: 3.5 mL/min

Quartz Crystal Microbalance QCM-D with Dissipation Module
-
Working temperature: 0 °C to 50 °C
-
Frequency range: 1 MHz to 50 MHz
- Maximum mass sensitivity in liquid: ~ 1 ng/cm2 (10 pg/mm2)
-
Maximum dissipation sensitivity in liquid: ~ 0.1 x 10-6
-
Typical noise: [Liquid: 1 Hz peak to peak (RMS)] - [Air: 0.1 Hz peak to peak (RMS)]
- Time resolution: ~600 ms
-
Input Voltage: 5 VDC
- Max current: 200 mA @ 5 VDC

Tweez 305 Turn-key Optical Tweezer System
-
Optical traps: 2500 time-multiplexed
-
Trap-to-trap switching rate: 100 kHz
-
Working field: 100 μm x 100 μm (with 60x microscope objective)
-
Camera: fast, high sensitivity 4 Megapixel (2048 x 2048) monochrome/color image sensor with pixel size 5.5 μm
-
Laser: 5 W CW, 1064 nm
-
Synchronization with external equipment: dedicated high speed Sync and Expansion ports
-
Power requirements: 100 – 230 V, 50 / 60 Hz